The Agilent HLD PR02 Leak Detector uses a mass spectrometer tuned to detect helium, which is used as a tracer gas to locate and/or measure very small leaks in enclosed devices or systems.

The compact and portable HLD PR02 is both a precise instrument and a robust workhorse, featuring an easy-to-use touch screen interface and menu structure that quickly connect users to powerful leak detection capabilities.

Built-in application setups shorten test cycles, and setups can be saved to assure repeatability.

It fits easily on a table, bench, or cart. The enclosed primary vacuum pump is the Agilent DS 40M rotary vane pump (pumping speed: 2 m3/hr).

 

 

 

 

 

Features


 

  • -Six different application setup guides help you correctly configure your instrument for the best performance, ensuring that parameters are properly set for a thorough and efficient test
  • -Large, durable, responsive, industrial touch screen rotates 180° for ideal viewing
  • -Clean, intuitive user interface allows immediate access to often-used features and a flat menu structure allows you to quickly find the setting you need
  • -Startup wizard simplifies set up on first-time power-up
  • -Enhanced charting capabilities include zoom for closer inspection of data, color-coded set points, and time-based plot records of leak rate and pressure
  • -A large work surface provides plenty of room for parts to be tested, tools, etc.
  • -Improved power-off process keeps spectrometer under vacuum and protects the turbomolecular pump

 

 

 

 

 

Information


 

Accessories & Options
  • Wireless remote (100 m)
  • Discrete IO interface
  • Harsh environment probe
  • Automated test fixture
  • Test fixture cable
Application Setup Guides
  • Sniffing
  • Spray Helium
  • Auto sequencer (programmable test cycle)
  • High sensitivity
  • Split flow
  • PPM sniffing
Calibration
  • Automatic internal and external
  • Able to check calibration while in test
Communications Interface
  • Analog output and Serial communications are standard
  • Optional discrete IO interface
Form Factor
  • Compact
Maximum Test Port Pressure
  • 13 mbar (10 Torr, 1333 Pa)
    200 mbar (150 Torr, 20000 Pa) in Gross Leak Mode
Primary Pump
  • Oil Sealed Rotary Vane Pump
Pumping Speed
  • 2 m³/h
  • 1.2 cfm
Selectable Languages
  • Chinese
  • English
  • French
  • German
  • Japanese
  • Korean
  • Russian
  • Spanish
Sensitivity
  • 5x10-12 mbar•L/s, 5x10-12 atm•cc/s, 5x10-13 Pa•m3/s
User Interface
  • 21 cm (8.4 inch) touch screen

 

 

 